Notes:
PSI = Maximum head height
divided by 2.31
To calculate the monthly cost
to operate a pump use the
following formula:
Amps x volts divided by
1000 x cost per kilowatt hour x
operating hours x 30.4 (average
days per month)
All Cal Pump tests are performed at
120 volts
Inline applications must be
installed below water level
The min/max ratings for both watts
and amperage are based on tests
performed by Cal Pump and are
for electrical installation reference
only. The minimum rating is based
on a pump tested in dry conditions
(motor only), while the maximum
rating is based on a pump tested
in water (with no attachment) at
a full load condition. These are
extreme conditions that are not
recommended when running any
Cal Pump product. Actual amp draw
will depend on your application and
should run in the mid-range of the
ratings on the performance chart.